Plumbing

New Assemblies

Backflow Preventer Installation
The Right Device, Placed Right

Adding irrigation, opening a business or told you need backflow protection? Our plumbers install backflow preventers matched to your hazard level, sized for your flow and tested on completion.

Choosing Correctly

Backflow Preventer Installation Matched to Your Hazard Level

The first question in any backflow preventer installation is what the device needs to protect against. A lawn sprinkler system, a restaurant’s soda machine, a dental office, a commercial boiler and a fire sprinkler line all present different risks. Codes and water utilities classify connections by degree of hazard and specify acceptable assembly types. Installing the wrong type can fail inspection, leave drinking water unprotected or require costly replacement once your utility reviews the installation.

Size matters just as much. A backflow assembly creates some pressure loss as water passes through its check valves, and reduced pressure assemblies typically lose more than other types. An undersized assembly can noticeably reduce flow to sprinklers, fixtures and equipment, while an oversized one adds unnecessary cost. Our plumbers confirm the required assembly type with your utility or local code, size it for your flow and pressure and choose an approved model from a recognized list.

Installations

Backflow Preventer Installation Services We Offer

We install backflow preventers for residential irrigation, domestic water services, fire sprinkler systems and commercial equipment, handling permits, utility approvals, enclosures and the initial certified test required before the assembly is placed into service.

Irrigation Assemblies

Install vacuum breakers or RP assemblies on lawn sprinkler systems.

Service Line

Install containment assemblies at the water meter or main service line.

Fire Line

Install double check or RP assemblies on fire sprinkler supply lines.

Equipment Protection

Protect boilers, carbonators, dental chairs and process equipment at the source.

Enclosures

Install insulated, lockable enclosures that protect assemblies from weather and theft.

Initial Testing

Test every new assembly and submit results to your water utility.

Placement

Placement Rules That Matter for a New Backflow Preventer

Where an assembly goes affects whether it works, whether it can be tested and whether it passes inspection. Reduced pressure assemblies discharge water from their relief valves when a check fails or pressure fluctuates, so they must be installed above ground, never in a pit that could flood, and where discharge can drain safely. Indoors, that means a floor drain or air gap fitting sized for the potential discharge, which can be substantial.

Pressure vacuum breakers must sit above the highest downstream outlet, such as the highest sprinkler head, to work correctly. Every assembly needs enough clearance around it for testers to connect gauges and for technicians to make repairs. Shutoff valves and test cocks must be accessible. Assemblies should also be protected from vehicle traffic, landscaping equipment and freezing. We plan placement around these rules and your property layout before installation begins.

Why Choose Us

Why Clients Choose Our Backflow Installations

We get backflow installations right the first time. Our licensed and insured plumbers confirm assembly requirements with your water utility, select approved models sized to minimize pressure loss and install them at correct heights with proper clearances and drainage. We handle permits, coordinate inspections and include the initial certified test. Enclosures, freeze protection and theft deterrence are offered where needed, so your assembly stays protected and compliant for many years.

Fast Service

Quick and Reliable Plumbing Services.

Qualified Team

Skilled and Certified Plumbers at Your Service.

Affordable Price

Competitive Quality Plumbing Solutions.

150+ Project Done

Our Track Record of Excellence.

Benefits of Professional Backflow Installation

Professional installation ensures your backflow preventer is the correct type for your hazard, meeting utility and code requirements the first time. Correct sizing protects water pressure for sprinklers, fixtures and equipment. Proper placement makes annual testing quick and repairs easier. Drainage planning prevents water damage when RP relief valves discharge. And including the initial test and paperwork means your new assembly is approved and in service without delays or extra appointments.

Protecting Backflow Assemblies From Freezing and Theft

Outdoor backflow assemblies face two common threats that can leave you with an expensive replacement and a failed compliance status. Both are preventable.

Even in mild climates, occasional hard freezes can crack brass bodies and damage internal parts in exposed assemblies. Insulated covers, heat tape or heated enclosures protect assemblies during cold snaps. Irrigation assemblies can also be drained before freezing weather when the system isn’t needed for watering.

Brass backflow assemblies are also targeted by thieves for scrap metal value, especially at commercial properties. Lockable steel cages or enclosures, anchoring and security hardware make theft much harder. We’ll recommend protection suited to your location, climate and risk, and install it alongside your new assembly.

How Our Backflow Preventer Installation Works

We review the connection being protected, confirm required assembly type with your water utility and measure flow and pressure needs.

You’ll receive a recommendation for the assembly model, size, location, enclosure and price. After permits are issued, water is shut off and the assembly is installed with shutoff valves and test cocks, at the correct height and clearance, with drainage provided for RP relief discharge.

Water is restored slowly, and the assembly is flushed and checked for leaks. A certified tester performs the initial test, and results are submitted to your utility. Required inspections are completed, enclosures or freeze protection are installed and we add the assembly to your annual testing reminder schedule.

24/7 Emergency Plumbing

Install the Right Backflow Protection

Need a new backflow assembly for irrigation, a business or fire protection? Our licensed plumbers handle backflow preventer installation from permit to test.

Frequently Asked Questions

Backflow Preventer Installation Questions Answered

Have Any Question on Your Minds?
Which backflow preventer do I need?

It depends on the hazard and local requirements. We confirm the required assembly type with your water utility before installation.

Some pressure loss is normal. Proper sizing and model selection minimize the effect on sprinklers, fixtures and any equipment downstream.

No. Reduced pressure assemblies must be installed above ground, since a flooded pit could allow contaminated water to enter through the relief valve.

Often yes. Many jurisdictions require permits and inspections for new backflow assemblies, plus an initial test by a certified tester.

Insulated covers, heated enclosures or draining irrigation assemblies before freezing weather protect brass bodies and internal parts from costly damage.

Scroll to Top